<h1>New SION Guidelines Detail Material Requirements for Copper, Aluminium Conductors in XLPE PVC Cables</h1> The Standard Input-Output Norms (SION) for the production of copper or aluminium conductors used in XLPE insulated, armoured or unarmoured PVC sheathed cables for 1100V/L.T. applications. It specifies the required quantities of materials per kilogram of export product: 1.01 kg of continuous cast copper rod or aluminium ingots, 1.05 kg of XLPE compound or cross-linkable LDPE compound, and 1.02 kg of steel armouring wire. For PVC compounds, it details the composition of PVC resin, plasticizer, and filler, with allowances for PVC stabilizers and paraffin wax subject to specific conditions.