<h1>New Norms for Manufacturing Aluminium Wound Transformers: Specified Material Quantities per KVA as per Foreign Trade Policy</h1> The Standard Input-Output Norms for manufacturing aluminium wound transformers ranging from above 100 KVA to 400 KVA, 3 Phase, Oil Cooled, as per the Foreign Trade Policy. It specifies the required materials and their quantities per KVA: CRGO Silicon electrical steel sheets/coils (2.20 kgs/KVA), Aluminium Winding Wires/strips (0.66 kg/KVA), Transformer Oil (2.52 kgs/KVA) or Transformer Oil Base Stock (2.77 kgs/KVA), Pre-compressed press board (0.30 kgs/KVA), and Phenolic Resin bonded paper (0.03 kgs/KVA). It also includes components like motorized tap changers and pre-pressed boards. If exported without the M.S. Tank and Transformer Oil, the allowance for Transformer Oil or its Base Stock is not permitted.