....pour absorption pump' use of which is admittedly as - ".......The Vapour Absorption heat pump is used to produce chilled water for using in our process and for maintaining temperature and humidity in different sections of Tyre Cord Plant. The manufacture of tyre yarn from wood pulp is highly temperature sensitive process. Viscose which is made from this wood pulp is very unstable at higher temp....

X X   X X   Extracts   X X   X X

Full Text of the Document

X X   X X   Extracts   X X   X X

....idity. The above condition of air is maintained by passing it through chilled water of spray of 6-8°C in the Air Washer. The chilled water used in above process get heated up and this heat is to be removed and chilled water temperature is to be brought down to 6-8°C. This is achieved by cooling the chilled water by the VAHP. Thus VAHP is necessary part of the manufacturing process for the fina....