<h1>Totally enclosed fan cooled induction motors: input norms specify per-kW material quantities and require import-use verification.</h1> Standard Input-Output Norms specify material inputs and per-kilowatt or per-motor allowances for totally enclosed fan cooled squirrel cage induction motors (0-0.75 kW, up to 660 V). Listed inputs include CRNO electrical steel or lamination core packs (20.54 kgs/KW; one stator and one rotor pack per motor), copper materials (1.90 kg/KW), pig iron or commercial aluminium for housing (14.00 kgs/KW or 4.63 kgs/KW), electrolytic aluminium for rotor (0.71 kg/KW), EN-8 shaft steel (2.08 kgs/KW), two bearings per motor, and composite insulation at 1.5% of FOB. Applicants must ensure imported inputs are those used or required in the export product.