Just a moment...

Top
Help
AI Drafter

Generate professional replies to Show Cause Notices, assessment orders, audit objections, and other legal communications using TaxTMI's AI Drafter.

Step 1 – Issue Identification & Review

The AI analyses your query, notice, order, or uploaded documents and identifies the key issues involved.

• Review the issues identified by the AI
• Add, edit, remove, or refine issues as required


Step 2 – Draft Generation

Once you approve the issues, the AI performs issue-wise legal research and prepares a structured draft response.

• Relevant statutory provisions
• Judicial precedents and Supreme Court, High Court and other citations
• Issue-wise legal analysis
• Practical arguments and supporting content
• Professionally structured draft ready for further review.

Try Now
×

By creating an account you can:

Logo TaxTMI
>
Call Us / Help / Feedback

Contact Us At :

E-mail: [email protected]

Call / WhatsApp at: +91 99117 96707

For more information, Check Contact Us

FAQs :

To know Frequently Asked Questions, Check FAQs

Most Asked Video Tutorials :

For more tutorials, Check Video Tutorials

Submit Feedback/Suggestion :

Email :
Please provide your email address so we can follow up on your feedback.
Category :
Description :
Min 15 characters0/2000
TMI Blog
Home / RSS

Parameters and facilities for testing furnace oil / waste oil -reg

X X   X X   Extracts   X X   X X

Full Text of the Document

X X   X X   Extracts   X X   X X

.... parameters prescribed in the aforesaid Board's Circular and the matter was taken up with Ministry of Environment & Forests & other expert agencies( IOC Ltd., IIP Dehradun etc.) for issue of further clarification / instructions . The doubts raised and parameters / procedure for testing fuel oils and off-specification products imported into the country were discussed and critically further reviewed in a meeting held on 09-03-2001 in the Ministry of Environment & Forests, which was attended by experts from various reputed research laboratories. After deliberations, stepwise procedure to be followed to determine whether an imported consignment is to be categorized as a fuel oil or off-specification product and further to classify an off-speci....

X X   X X   Extracts   X X   X X

Full Text of the Document

X X   X X   Extracts   X X   X X

....nace oil of viscosity below 370 centistokes should be categorized into the following four grades of fuel oils : (1) Viscosity upto 80 centistokes (Grade LV) , (2) Viscosity 80 to 125 centistokes (Grade MV 1), (3) Viscosity 125 to 180 centistokes (Grade MV 2) , and (4) Viscosity 180 to 370 centistokes (Grade HV) . 5. The above four grades could be tested for total sulphur per cent by weight (1) Grade LV viscosity up to 80 centistokes should confirm to a maximum of 3.5% suphur by weight . (2) Grade MV1 viscosity 80 to 125 centistokes and Grade MV2 from 125 to 180 centistokes viscosity should confirm to a maximum total sulphur of 4% by weight . (3) Grade HV from 180 to 370 centistokes viscosity should confirm to a maximum total sulphur of 4....

X X   X X   Extracts   X X   X X

Full Text of the Document

X X   X X   Extracts   X X   X X

....s conforming to heavy metal concentrations listed in Appendix 1 for re-refining could be re-refined and those not confirming should be classified as hazardous waste . (ii) Products/furnace oil indicating presence of organic halide should be tested for PCBs. (iii) Samples testing negative for PCBs but showing presence of organic halides should be tested for heavy metals . Samples confirming to heavy metal concentration listed in Appendix 1could be re-refined . Those not meeting the specifications laid down for heavy metals should be classified as hazardous waste. 10. Samples testing positive for organic halides and PCBs should be classified as hazardous waste. The above procedure may be brought to the notice of all concerned for complian....