<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" href="https://www.taxtmi.com/rss_sitemap/rss_feed_blog.xsl?v=1750492856"?>
<rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom">
  <channel>
    <title>Notification Specifying the procedure for testing of breathing apparatus, flow meter and purity of oxygen for use in breathing apparatus under Rule 131(5) of the Occupational Safety, Health and Working Conditions (Central) Rules, 2026</title>
    <link>https://www.taxtmi.com/notifications?id=146265</link>
    <description>Specifies the procedure for testing breathing and resuscitating apparatus, flow meters and the purity of oxygen used in breathing apparatus. The standard applies to apparatus in rescue stations and rescue rooms and requires periodic testing of condition, leakage, cylinder pressure, relief valve discharge pressure, oxygen delivery rate and automatic demand valve operation, with records kept in bound or non-editable electronic form. Oxygen purity must be tested, and oxygen containing more than one per cent impurities must not be used. Apparatus testers must also be checked for accuracy at manufacturer-recommended intervals.</description>
    <language>en-us</language>
    <pubDate>Wed, 01 Jul 2026 00:00:00 +0530</pubDate>
    <lastBuildDate>Wed, 08 Jul 2026 11:44:00 +0530</lastBuildDate>
    <generator>TaxTMI RSS Generator</generator>
    <atom:link href="https://www.taxtmi.com/rss_feed_blog?id=910716" rel="self" type="application/rss+xml"/>
    <item>
      <title>Notification Specifying the procedure for testing of breathing apparatus, flow meter and purity of oxygen for use in breathing apparatus under Rule 131(5) of the Occupational Safety, Health and Working Conditions (Central) Rules, 2026</title>
      <link>https://www.taxtmi.com/notifications?id=146265</link>
      <description>Specifies the procedure for testing breathing and resuscitating apparatus, flow meters and the purity of oxygen used in breathing apparatus. The standard applies to apparatus in rescue stations and rescue rooms and requires periodic testing of condition, leakage, cylinder pressure, relief valve discharge pressure, oxygen delivery rate and automatic demand valve operation, with records kept in bound or non-editable electronic form. Oxygen purity must be tested, and oxygen containing more than one per cent impurities must not be used. Apparatus testers must also be checked for accuracy at manufacturer-recommended intervals.</description>
      <category>Notifications</category>
      <law>Labour laws</law>
      <pubDate>Wed, 01 Jul 2026 00:00:00 +0530</pubDate>
      <guid isPermaLink="true">https://www.taxtmi.com/notifications?id=146265</guid>
    </item>
  </channel>
</rss>